BLOG    CAREERS     LOGIN         

COVID-19 vaccine distribution monitoring made easy

The global COVID-19 vaccines distribution task is a complicated operation and implementing an easy solution to monitor this process is more important than ever. COVID-19 vaccines need to be stored at specific temperatures, which means that the cold chain of these vaccines must be carefully monitored. SenseAnywhere has a simple, effective, and reliable solution to this: Transport alarms which show you whether the sensitive goods have been transported under the right conditions or not. A perfect solution that gives peace of mind to COVID-19 vaccine distributors.

The COVID-19 distribution is a challenge: It has to be organised quickly while nothing must go wrong. The problem is that there is little experience with one of the most complex logistical challenges we have ever faced on this planet. Accurate temperature monitoring of the new vaccines is key because storage and distribution at incorrect temperatures can decrease the quality, safety and effectiveness of the vaccines. Vaccines from different suppliers all need to be stored at different temperature ranges, which van all be perfectly monitored with SenseAnwhere AiroSensors.

Get real-time alerts on vaccine temperature conditions with SenseAnywhere Transport Alarms
SenseAnywhere offers ‘Transport Alarms’ as a solution that makes things easy, SenseAnywhere’s revolutionary ‘Set & Forget’ system means that you can set up the data loggers and simply leave them to operate, safe in the knowledge that measurements are recorded every 5 minutes 24/7. The only required action is to start and stop the transport monitoring with a SwitchHolder or QR code scan and select the right monitoring profile. Furthermore: no human intervention and no prone to error. Should a deviation occur then an email or SMS will be generated automatically, giving you essential time to intervene to protect your vaccines. The AiroSensor never stops logging. Data is fully automatically transferred, stored, and archived for at least 10 years. Even if you forget to start or stop the transport alarm you still have the temperatures over that period as the AiroSensor works always.

Access COVID-19 vaccine temperature data 24/7 via QR code scan or SwitchHolder
To use Transport Alarms, all you need is to scan a QR code on the outside of the transport packaging or an AiroSensor inserted in a SwitchHolder mounted in the container. At the start of the transport – at COVID-19 vaccines manufacturing sites – the transport alarm can be started by either scanning the QR code or sliding the AiroSensor in the SwitchHolder to “on”. The carrier can enter a unique tracking ID of its transport in the SAClient Portal to link the transport to the shipment. When the vaccines arrive at the clinic, the transport alarm can be stopped by scanning the QR code again or sliding the SwitchHolder to “off”. The shipper can use the same tracking ID in SAClient to quickly find his transport. Once arrived, the shipper will receive an email or SMS, stating whether the temperature limits have been exceeded or not. It couldn’t be easier. SenseAnywhere is your reliable partner.

SwitchHolder Transport Alarms

  • Prepare the box for shipment.
  • Enable the SwitchHolder to Start the Transport. Monitoring plus generating alarms if any.
  • Realtime alarms when Mobile AccessPoint is in vehicle or Logging when outside the network.
  • Cooling Unit has arrived at its destination.
  • Disable the SwitchHolder to Stop the Transport. Triggers report (email, SMS alarms if any).
  • Automatically generated report, stored for at least 10 years.
    • Paperless.
    • No human intervention in data collection and storage.

QR Scan Transport Alarms

  • Prepare the box for shipment.
  • Scan the QR Code and Start the Transport. A content. description can be linked to this Transport Alarm.
  • Realtime alarms when Mobile AccessPoint is in vehicle or Logging when outside the network.
  • Cooling Unit has arrived at its destination.
  • Scan the QR Code and Stop the Transport. View Transport Results.
  • Automatically generated report, stored for at least 10 years.
    • Paperless
    • No human intervention in data collection and storage

Simply Smarter
SenseAnywhere is specialized in fully automated temperature monitoring for the Pharmaceutical industry. Its system work globally and is extremely suitable for pharmaceutical companies or large organisations and cold chain distribution. The SenseAnywhere Monitoring System is cost-effective and very quick and easy to deploy on a “Plug and Play” basis. Due to the excellent measuring capacity of the sensors, measurements are accurate and extremely reliable. The software is developed according to the GAMPS rules, validated, and SenseAnwhere can provide IQ OQ Documentation Sets. SenseAnywhere is ISO 9001 and ISO 27001 certified and the organisations performs regular penetration tests. And on top of that, the AiroSensors are extremely energy-efficient and durable, with a battery life of 10 years. SenseAnywhere, Simply Smarter.

Share:

Subscribe to our newsletter

Set up alarms in SAClient

How to set up alarms in SAClient?

  • You can setup alarms for each of your Sensors under Alarm > Profile. To set up a new alarm profile for your Sensor, click on the “Add New Alarm Profile” button at the bottom of the screen.
  • You’ll be guided to a screen where you can set up your alarm. Here, you can name the alarm, select from various Alarm Types, and choose the corresponding logger. You’ll also have the option to define specific parameter limits that trigger the alarm, opt for a delay or reminders.
  • Assign a specific user within your account to receive these notifications. The users assigned to this alarm can receive an alert via email, SMS or Voice based on their preference.
  • Select the “Save” button at the bottom of the screen once all these fields are complete.

Access your data in SAClient

How to access your data in SAClient?

  • Log in to the SAClient Portal. You get access to a Dashboard with real-time information on status of your devices. You can access data for your Sensors under the Overview section.
  • Detailed Data visualized in charts can be accessed under Overview > Data Analysis. Choose on the left hand sided drop-down menu the desired Sensor. You also can change the Period. Choose on the right sided drop-down menu the desired Data. Then Click “Go”.
  • Data can also be exported by pressing the “CSV” button on the bottom of the page.
  • To download an image of the chart, simply click the three lines on the right side and select your preferred export format.
  • Access your data in SAClient

How to register your 20-20-31?

How to register your 20-20-31?

  • To register the Sensor, remove it from its holder and locate the serial number on the back.
  • Register the device under Management > Register Device in SenseAnywhere Cloud with the serial number.
  • After successful registration, place the Sensor back in its holder. Your logger should now be online and visible in the system.

Register your sensor and Pt100

How to register your AiroSensor and Pt100 Probe?

  • The AiroSensor 20-20-43 and the Pt100 Probe can be registered in the SAClient Portal by navigating to Management > Register Device.
  • The AiroSensor 20-20-43 does not need to be removed from the holder. To register the AiroSensor, you will need the serial number which can be found on the box.
  • To register the Pt100 Probe, perform the same steps as you did for the AiroSensor. The serial number can be found on the bag or on the Probe itself. You only need one license to register the logger. The registration of the Module is free.
  • Once registered, they will appear in your list of devices on your home page dashboard.
  • After registering the Pt100 Probe, the settings and name can be changed under Management > Sensor. Select the pencil icon, then edit and click “Save”.

INSTALL YOUR ACCESPOINT

Find the right location to install your AccessPoint, keeping the following in mind. The AccessPoint uses radio signals to communicate with the Sensors wirelessly.

To get the best possible reception:

  • Place the AccessPoint as close as possible to the location of the loggers.
  • If the area that needs to be covered is large, place multiple AccessPoints at different locations in the building/at the site.
  • Mount the AccessPoint in a vertical position. There is a keyhole on the back that can be used to hinge the AccessPoint on a screw.
  • If the location allows it, hang the AccessPoint in free air suspended by its cables.
  • See the AccessPoint as an antenna; actually, the antenna is integrated into the AccessPoint.
  • Do not mount the AccessPoint close to or on a metal surface.
  • Try to avoid mounting the AccessPoint on concrete walls.
  • Try to avoid concrete walls or floors between the AccessPoint and the loggers.
  • Try to avoid mounting the AccessPoint on thick wooden beams.
  • Try to avoid metal walls or surfaces between the AccessPoint and the loggers. Also, modern windowpanes with sunscreen protection (a thin metal film) obstruct wireless signals significantly.

Troubleshooting Tip:
If the LED on the AccessPoint does not turn green, you do not have an Internet connection at this moment, or your firewall is blocking outgoing TCP/IP connections on port 80. If you have internet access but the AccessPoint does not turn green, you should add the Ethernet MAC address range of the SenseAnywhere AccessPoints (00:21:5B:00:00:00) to (00:21:5B:FF:FF:FF) to the “allow table” in your firewall for outgoing communication. The AccessPoints use only TCP/IP communication over port 80. It is not necessary to open any incoming ports in your firewall.

Power over Ethernet (PoE)
Would you like to power your AccessPoint via Ethernet cable? Get a Power-over-Ethernet (PoE) cable set from your SenseAnywhere reseller. This kit merges power from the adapter and switch, delivering both via a standard Ethernet cable. Choose between passive (white) and active (black) sets based on your switch type:

  • Passive PoE (White Set): Merge power from the adapter and data from the switch using the combiner at the switch location. Split them at the AccessPoint using the splitter.
  • Active PoE (Black Set): If you have a PoE-enabled switch, it provides both power and data. Simply split them using the black active PoE splitter before reaching the AccessPoint.

REGISTER YOUR ACCESPOINT

How to register your AccessPoint?

  • In the SAClient Portal, under Management > Register Device, you can register various devices, such as AccessPoints, AiroSensors, Modules, and AssetTags. To register your AccessPoint, you will need the serial number located on the back of the device.
  • Once registered, the AccessPoint will appear in your list of devices on your home page dashboard.
  • Under Management > Location, you have the option to add a location. To edit the name and location of the AccessPoint, go to Management > AccessPoint, select the pencil icon, edit and click “Save”.

HOW IT WORKS

Welcome and thank you for your trust in SenseAnywhere!

Your package includes several items:

  • A welcome card with all the information you need to get started and a Pin code to create your account with Credits.
  • The Pt100 Probe for measuring ultra-low or high temperatures. The serial number can be found on the bag or on the Probe itself.
  • The required cables and adapter for connecting the AccessPoint.
  • The AssetTag for easy swapping of AiroSensors, without losing data.
  • The AiroSensor 20-20-43 that can be connected to different Modules.
  • And finally, the AccessPoint to connect the Sensors to SenseAnywhere’s Cloud Service. The serial number can be found on the back.

For instructions on creating your account and adding Credits, please refer to the welcome card or visit www.saclient.com/redeem.